XGSLab is developed by SINT Ingegneria, an Italian engineering, consulting and software development company. The company has been working in the electrical engineering field since 1980.

XGSLab Grounding Solution

EasyPower is partnering with the industry-leading grounding and EMI analysis expert company, SINT Ingegneria (website), which offers a software package to analyze and design grounding, lightning and electromagnetic interference problems by focusing on its powerful and yet affordable grounding analysis software packages, XGSLab. EasyPower is the exclusive representative of XGSLab software in the USA and Canada.

Do you have questions or want a quote? Contact Ron Levasseur at 503-655-5059 x62, or ron@easypower.com.

XGSLab

XGSLab (Over and Under Ground System Laboratory) is one of the most powerful software packages for grounding system analysis, electromagnetic fields, interference and lightning analysis and the only software on the market that takes into account both EN and IEEE Standards.

XGSLab includes the modules:

All modules are integrated in an “all-in-one” package and based on a hybrid calculation method (or “PEEC” method) which considers transmission line, circuit and electromagnetic theory combined into a single calculation model.

Hybrid methods join the strong points of the other methods and are well suited for engineering purposes because they allow the analysis of complex scenarios including external parameters such as voltages, currents and impedances. For these reasons, XGSLab can be considered a real laboratory.

Applications

The following table summarizes the main applications of the available models.

Application GSA GSA_FD XGSA_FD
Grounding (small systems) Yes Yes Yes
Grounding (large systems) No Yes Yes
Cathodic Protection Systems No Yes Yes
Magnetic Field No Yes Yes
Electric Field No No Yes
Electromagnetic Interferences No Yes Yes
Fault Current Distribution No No Yes
Lightning effects for a single frequency No No Yes

 

XGSA_TD can be applied to analyze in the time domain, current and potential distribution on underground and overhead conductor networks energized by means current or voltage transients. It can calculate the consequent distributions of earth surface potentials and electric and magnetic fields.


Product Details

GSA (Grounding System Analysis)

GSA_FD (Grounding System Analysis in the Frequency Domain) 

XGSA_FD (Over and Under Ground System Analysis in the Frequency Domain)

XGSA_TD (Over and Under Ground System Analysis in the Time Domain)